Condensation or a leak: telling them apart
Water on the inside of a skylight can come from humid air condensing on a cold surface, or from water entering the frame, and the two need different fixes.
Condensation tends to appear on cold mornings, forms across the glass rather than in a line, and clears as the room warms. A leak tends to appear during rain, follows a path along the frame or the flashing, and does not depend on the temperature of the room. The first can often be reduced by ventilation and humidity control, while the second needs the roof fixed.
The distinction is worth making before any work begins, because a skylight replaced to stop condensation will still leak if the flashing is the cause. The roofer records the pattern of the moisture, the weather when it appears and the place it first shows, and uses those notes to decide the scope.
The curb and the flashing
The curb holds the unit and the flashing keeps water out of the joint, and both have to be right for the unit to perform.
The curb is the upstand the unit sits on, and it is usually framed from the same rafters and headers as the opening. Its wood must be sound and its corners must be tight, because movement at a corner opens a route for water into the framing. Where the curb is damaged, it is rebuilt before the unit goes back in.
The flashing around a skylight is made of several pieces. The upslope piece is the most important, because it carries water over the top of the unit. The head piece and the side pieces lap over the courses of the roof, and the sill piece sheds water downhill. Each has to be set in order, so the water always runs over the metal and never under it.
- Curb wood sound, tight at each corner and free of rot
- Upslope flashing set beneath the courses above it
- Side flashing lapped over the roof courses at each edge
- Sill flashing sending water clear of the lower curb
Choosing the unit and its glazing
The unit is chosen for light, insulation and how the room will be used, and its glazing is matched to the climate of the space it lights.
A skylight's glazing affects how much heat it lets through, how much light reaches the room and how much noise and condensation it produces. Insulated units with multiple panes reduce heat loss and condensation at the glass, and a tinted or coated pane can cut glare. The choice should be made with the room beneath in mind rather than from the catalog alone.
The unit's size, its slope and the framing around it are part of the same decision. A larger unit needs stronger framing, and a unit set too low on the slope sheds water less efficiently. The roofer checks each of these against the opening and recommends a size the curb can support.
Framing changes and the opening
A new skylight is sometimes a chance to change the opening, and any change to the framing has to be scoped and checked.
Enlarging or moving an opening means cutting rafters and fitting new headers, which alters the structure of the roof and counts as altering the building. In Baltimore City that work falls under the city's permit requirement, and the roofer should confirm the permit before any rafter is cut.
Where the opening stays the same size, the framing is checked and repaired but not changed. That is the simpler job, and it is usually the right one when the existing position is sound and the only problem is the unit and its flashing.
Installing and testing the new unit
The new skylight is set, secured and water-tested before anyone signs off the job, because the test is the only real proof of the flashing.
Once the flashing is in place, the unit is lowered onto its curb, shimmed level and fixed to the framing with the fixings the manufacturer specifies. The interior trim and any insulation around the frame are then finished, and the glazing is checked for seals and for any scratches from fitting.
The water test is run after the unit is secured and before the surrounding covering is finished. The homeowner should watch it, because a joint that passes a test is one that has been seen to pass.