Why the joint leaks at the wall
Flashing fails at the wall because the masonry moves, the sealant ages and the metal was never set into a proper channel.
Brick and mortar expand, contract and settle at different rates, and a joint between roof and wall must follow that movement without tearing. Sealant laid over the surface of the flashing cannot do that for long. It cracks at the edges, pulls off the metal and leaves a path for water that runs straight down the inside of the wall.
The metal itself often fails at its top edge. Flashing that was fixed with nails into the mortar, or simply tucked into a joint without being cut into a channel, will lift when the wall moves. The water then gets behind the base flashing and runs along the framing until it finds a route into the room below.
Counter-flashing and the reglet
Counter-flashing sheds water down over the base flashing, and the way it is set into the wall decides how long it lasts.
Counter-flashing is the outer metal that covers the top edge of the base flashing. It has to be set into a reglet, a narrow channel cut into the mortar, so that it is held firmly and so that the edge is covered from above. A reglet that is too shallow lets the metal pull out; one that is too deep weakens the brick around it.
A good counter-flashing is bent over the base with a clear overlap and sealed only at its top edge, not across its full face. That leaves room for the metal to move and keeps water from being trapped between the two layers, which is the usual reason sealed-faced details fail early.
- A reglet cut deep enough to hold the metal under movement
- Counter-flashing bent over the base with a clear overlap
- Sealant only at the top edge, never across the full face
- Metal of a gauge matched to the length of the run
Caps, coping and the drip
The cap is the top of the wall, and its overhang and drip are what keep water off the face of the masonry.
A cap that is level or slopes back toward the wall holds water on top of the parapet, where it soaks into the brick and freezes and thaws through the winter. A cap that slopes outward and overhangs both faces sheds the water clear, and a drip cut or formed on its underside stops the water from running back along the face.
Coping can be stone, precast, or metal, and each has its own joints that need sealing at the ends and at any seam. The roofer checks each joint, because a single open joint can carry water a long way into a wall before the stain shows on the inside.
Testing the joint before closing it
A joint is tested with water, not with a look, because a flashing that looks sound can still pass water along the metal.
Water is run from a hose on the roof side, starting below the joint and working up so each section is wetted in turn. The person checking stands inside the attic or the top-floor room and watches the framing and the wall face while the water runs. A joint that passes the test is one the homeowner has watched pass.
If water appears, the source is found before the joint is closed. The roofer does not assume the leak is where the stain is; the test shows where the water actually crossed the line, and that point is the one that is repaired and tested again.